Product Comparison
Number of channels
4 channels(supports SD33、SD22、and SD-C series) When using two or more sensors the sensor heads must be of the same model
Communication method
RS-485(maximum cable length 20m)
Supported protocol
SinceVision self-developed protocol Modbus protocol
Supported performance
PDO: Maximum 4kHz refresh rate SDO: Supports sensor parameter settings
Physical interface
Double-row 24-pin pluggable European connector
Version
EtherCATSlave
Standard protocol
IEEE802.3u(100Base-TX)
Transmission rate(Mbps) (Mbps)
100 Mbps
Communication cycle(μs) (μs)
250 μs
Transmission distance(m) (m)
Maximum distance 100 m
Communication cable
STP CAT.5E or higher
Number of ports
2 input/output ports
Physical interface
RJ45
IP protection level (dust)
IP50
Working temperature(°C) (℃)
-20~50 ℃
Overall dimension (mm) (mm)
103.5(H)x34(W)x110(D) mm
Shell material
Plastic
Installation type
DIN rail